ESR-NMR Control Unit

ESR-NMR Control Unit, 1022700, Magnetic Resonance
ESR-NMR Control Unit, 1022700, Magnetic Resonance
$ 1,585.00

Voltage:

115V, 50/60 Hz
230V, 50/60 Hz
More on the way
More on the way

Applications and Experiments: ..
This control unit controls the ESR module and the NMR module, allowing the following topics to be explored and experiments to be performed:..
• Resonance absorption of a high-frequency resonant circuit
• Dependence of the resonance frequency on the magnetic field
• Electron spin and magnetic moment of the electron
• Determination of the electron g-factor; Landé g-factor of the free electron
• Proton spin and magnetic moment of the proton and of the nucleus
• Determination of the nuclear g-factor
• Magnetic resonance imaging

Product Information: ..
This control unit is required to operate the ESR module (item no.: 1022705). Together, the two devices enable the investigation of electron spin resonance (ESR) of the unpaired electron in DPPH (2,2-diphenyl-1-picrylhydrazyl) molecules.
It is also required to operate the NMR module (item no.: 1022706) and investigate nuclear magnetic resonance (NMR) in glycerin, polystyrene, and Teflon®.
The resonances are observed by means of radio-frequency-induced transitions as the external magnetic field is varied. The resonance absorption curves can be displayed using a simple two-channel oscilloscope or WiLab.
This control unit supplies the control voltages and supply voltages required by the ESR or NMR module, conditions the measurement signal for display on an oscilloscope, and displays the frequency of the RF signal.

Specifications: ..
Measuring head connection: Four-pole LEMO socket
Pair of coils connection: Sawtooth current source; 0 − 250 mA; 50 ms
Magnetic field output: Proportional to the coil current; 0 − 1 V; BNC socket
Signal output: .. Resonance signal; 0 − 1 V;  BNC socket ..
Frequency range: 45 − 75 MHz (ESR) approx. 
 .. 10 − 15 MHz (NMR) approx.  ..
Power supply: Plug-in power supply; 12 V AC; 2.0 A
  Coaxial power connection; 5.5 mm x 2.5 mm, 
 .. Cable length: 2 m ..
Operating temperature: 5 °C − 40 °C
Relative humidity: .. < 80 % (without condensation) ..
Dimensions: 170 mm x105 mm x 45 mm approx. 
Weight: 500 g approx. 
   
Electromagnetic
Compatibility:
Emission:  EN 55011:2009
Immunity: DE 61326-1:2013
   
Electrical safety: Safety regulation DIN EN 61010-1
  Safety regulation DIN EN 61558-2-6
   
Transformer: Safety isolating transformer according to DIN EN 61558-2-6 
Protection class: 2
Pollution degree: 2
Degree of protection:  IP20

Scope of Delivery: ..
1 ESR-NMR control unit
1 Desktop power supply; 12 V AC; 2.0 A
1 Product manual

Additionally required: ..
1 ESR module (item no.: 1022705)
or
1 NMR module (item no.: 1022706)
   
1 Digital oscilloscope 2 x 30 MHz (item no.: 1020910)
or
1 PC oscilloscope 2 x 25 MHz (item no.: 1020857)
   
2 RF cables, 1 m (item no.: 1002746)

Item No.: 1022700
Weight 2.31 lb
Brand 3B Scientific
  • Secure online payment with SSL
  • Expert advice
  • Financing available
  • Easy returns & exchanges
  • International shipping available
Service hotline:
1-888-326-6335