Franck-Hertz-Experiment:
The quantization of energy, as well as the generation, registration, and analysis of spectra and the associated experimental confirmation of models, are important components of most curricula around the world. The ...
еще
Franck-Hertz-Experiment:
The quantization of energy, as well as the generation, registration, and analysis of spectra and the associated experimental confirmation of models, are important components of most curricula around the world ...
еще
Replacement mercury tube for the Franck-Hertz experiment with mercury.
Replacement mercury tube* for the Franck-Hertz experiment with mercury:
Franck-Hertz tube with Hg filling and heating furnace (115 V /50/60 Hz); article no ...
еще
Experiment topics:
• Linear propagation of electrons in a zero-field space
• Deflection of electron beams in an electrical field
• Deflection of electron beams in a magnetic field
• Magnetic lens
• Phase displacement ...
еще
The quantization of energy and the generation, recording and evaluation of spectra, along with the experimental verification thereof, is included in most of the curricula used around the world. The well known experiment first performed by James ...
еще
Блок питания для трубки Франка-Герца, наполненной ртутью (U8482550-230 или U8482550-115), трубки Франка-Герца, наполненной неоном
(U8482230), или трубок определения критического потенциала возбуждения атомов (U18560 и U18565). Данное обор ...
еще
Electric heating chamber with continuous temperature control and digital temperature display showing actual and set-point temperatures. In lacquered metal housing with two viewing windows, opening with spring-clip for thermometer and thermally ...
еще
Electric heating chamber with continuous temperature control and digital temperature display showing actual and set-point temperatures. In lacquered metal housing with two viewing windows, opening with spring-clip for thermometer and thermally ...
еще
Adapter for electron diffraction tube D (U19171) for connection of the heater voltage via safety experiment leads. Includes internal protective circuitry to protect the heating filament against excess voltage. Dimensions match the three-pole ...
еще
Adapter for electron tubes D for connection of the heater voltage via safety experiment leads. Includes internal protective circuitry to protect the heating filament against excess voltage. Dimensions match the two-pole connector for the tubes ...
еще
Spare Tube for Complete Fine Beam Tube System 1013843.
Gas filling: Neon
Gas pressure: 1.3x10-5 hPa
Bulb diameter: 165 mm
Orbit diameter: 20 … 120 mm
Measurement mark spacing: 20 mm
еще
Experiment Topics:
Deflection of electrons in a closed circular path inside a magnetic field.
Determination of specific charge of an electron e/m.
For examining the deflection of electron beams in a uniform magnetic field ...
еще
Tube holder made of robust plastic for holding electron tubes of the D series and the optical analogy tube (U19172).
With 360o rotating clamp made of heat-resistant plastic and two holes for fixing the demonstration Helmholtz coil pair ...
еще
Pair of Helmholtz coils for generating a uniform magnetic field perpendicular to the axis of the Teltron D series tube. Consists of two coils in a plastic casing on an insulated stand rod.
Coil diameter: 136 mm
Number of ...
еще
The Teltron Auxilary Coil generates two perpendicularly aligned magnetic fields in conjunction with the Teltron Helmholtz Coils D.
Deflect the electron beam in the Teltron Perrin Tube D to generate Lissajous figures!
Number of turns: ...
еще
Highly evacuated electron tube with thermionic cathode and anode for investigating the thermoelectric effect (Edison effect) and measuring the emission current as a function of the heating power applied to the cathode. Also for plotting diode ...
еще
For quantitative investigations of controllable high-vacuum tubes. This includes recording triode characteristics, determining the negative polarity of electron charges and generating cathode radiation (model of an 'electron gun'). ...
еще
Highly evacuated electron tube with divergent electron gun and three fluorescent strips in red, green and blue. For demonstrating stimulated light emission during and after electron bombardment.
Filament voltage: 6.3 V AC
Max. Anode voltage ...
еще
For demonstrating the straight propagation of electron beams in field-free spaces by projecting the shadow of a Maltese cross on a fluorescent screen. Also intended for observing the focussing of electron beams by magnetic fields as an introduction ...
еще
The Teltron Perrin Tube D demonstrates the negative polarity of electron beams through magnetic deflection. The electron beams are deflected toward a Faraday cage connected to an electroscope.
Experiments:
• Investigate the operation ...
еще
Highly evacuated electron tube with focusing electron gun and fluorescent screen inclined relative to the beam axis, so that the path of the beam can be seen and the effects of electric and magnetic fields can be studied. The electron beam ...
еще
For quantitative investigations of the typical properties of a gas-filled triode, recording the IA - UA characteristics of a thyratron. Observing independent and dependent discharges as well as discontinuous energy release of He atoms during ...
еще
Part evacuated electron tube, filled with neon at low pressure, with tangential and axial electron gun. For determining specific charge e/m from the diameter of the filament beam in the case of tangential bombardment and a perpendicularly aligned ...
еще
Highly evacuated electron tube for determining the wavelength of electrons as a function of the anode voltage from the radii of the diffraction rings and the distance between the lattice planes of graphite (Debye-Scherrer-diffraction) and rendered ...
еще