For electrical circuits with low voltages and high currents; copper wire encased in highly flexible PVC; equipped at either end with a laminated plug and a fully-insulated axial jack for connecting additional patch cords.
Wire cross ...
more
Compact equipment for recording charging and discharging curves for capacitors
at individual points. Includes 12 V AC plug-in power supply.
The charger and discharger consists of three units in a single housing: a voltage
comparator, a digital ...
more
Complete equipment for recording charging and discharging curves for capacitors
at individual points. Includes 12 V AC plug-in power supply.
The charger and discharger consists of three units in a single housing: a voltage
comparator, a ...
more
Metal stem with knurled screw and 4 mm bore hole on acrylic rod, as insulated holder for wires, e.g. when conducting experiments on the optical bench are performed.
Diameter: approx. 10 mm
Length: approx. 100 mm
more
Replica of Alessandro Volta’s apparatus consisting of series-connected galvanic cells to make up a source of electricity.
Zinc and copper plates stacked in alternation on top of each other are separated in each case by a piece of felt ...
more
Switch attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Maximum voltage: 12 V
Maximum current: 5 A
Dimensions: 135x85x40 mm³
more
Normally open push-button switch attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Maximum voltage: 12 V
Maximum current: 2 A
Dimensions: 135x85x40 mm³
more
Knife-edge switch attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Maximum voltage: 12 V
Maximum current: 5 A
Dimensions: 135x85x40 mm³
more
Fuse holder attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Fuses (not included): 20 mm x 5 mm diam.
Maximum voltage: 12 V
Maximum current ...
more
Pair of crocodile clips for connecting loose resistors and other electronic components or samples from the “Conductors and Non-Conductors” set. Attached to a safe box for building simple electric circuits using safety experiment leads. Printed ...
more
Universal holder for two-pole components (resistors, capacitors, diodes, LEDs) attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Dimensions: 135x85x40 mm³
more
1N4002 semiconductor in an electrically safe box for assembling simple electric circuits using safety experiment leads. Featuring printed circuit symbol.
Maximum voltage: 12 V
Maximum current: 1 mA
Dimensions: 135x85x40 mm³
more
Low-voltage motor with pulley for simple experiments on mechanical and electrical energy. The relationship between current direction and direction of rotation is immediately obvious.
Built onto an electrically safe box for assembling simple ...
more
LED on an electrically safe box for assembling simple electric circuits using safety experiment leads. Featuring built-in current limiting resistor and printed circuit symbol.
Maximum voltage: 12 V
Maximum current: 20 mA
Dimensions: 135x85x40 ...
more
LED on an electrically safe box for assembling simple electric circuits using safety experiment leads. Featuring built-in current limiting resistor and printed circuit symbol.
Maximum voltage: 12 V
Maximum current: 20 mA
Dimensions: 135x85x40 ...
more
Battery holder in an electrically safe box for assembling simple electric circuits using safety experiment leads. Printed circuit symbol and battery direction. Batteries not included.
Battery: 4.5 V, 3R12, flat battery
Dimensions: 135x85x40 ...
more
600-winding coil without core attached to a safe box and featuring safety sockets. For experiments on induction, a bar magnet can be passed through the coil.
Dimensions: 135x85x40 mm³
more
Single-pole double-throw change-over switch attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Maximum voltage: 12 V
Maximum current: 5 A
Dimensions: 135x85x40 mm³ ...
more
Bridge rectifier circuit consisting of four semiconductor diodes connected in Graetz configuration. Inside a safe box for building simple electric circuits using safety experiment leads. Printed with circuit symbols.
Maximum voltage: 12 V ...
more
Bridge rectifier circuit consisting of four LEDs connected in Graetz configuration. Inside a safe box for building simple electric circuits using safety experiment leads. Printed with circuit symbols.
Maximum voltage: 12 V
Maximum current ...
more
Circuit comprised of two LEDs for indicating the direction of current. Inside a safe box with sockets for safety experiment leads. Printed with circuit symbols.
Maximum voltage: 12 V
Maximum current: 20 mA
Dimensions: 135x85x40 mm³
more
Classic set-up for verifying Ohm’s law for a two-pole resistor. Inside a safe box with sockets for safety experiment leads. Printed with circuit symbols.
Maximum voltage: 12 V
Maximum current: 2 A
Dimensions: 135x85x40 mm³
more
Four unknown resistors which can be connected separately in two series circuits. Inside a safe box with sockets for safety experiment leads. Printed with circuit symbols.
Maximum voltage: 6 V
Maximum current: 200 mA
Dimensions: 135x85x40 ...
more
Capacitor in plastic housing with 4 mm safety plugs.
Capacitance: 2200 μF
Tolerance: 20%
Maximum permissible voltage: 40 V
Dimensions: approx. 122x70x50 mm³
more
High-Precision Resistors in plastic housing with 4 mm safety plugs.
Specifications:
Dimensions: approx. 122x70x50 mm³
Resistance: 300 kΩ
Tolerance: 5%
Load rating: 3 W
more
Apparatus to investigate the dependency of electrical resistance on conductor length, conductor cross-section and material. Six wires are laid out side by side on a metal base and both ends connect to 4 mm sockets.
Wire specimens: Constantan ...
more
Lamp socket on transparent acrylic base with screw connection for ordinary commercial filament bulbs for E10 sockets. Sockets for 4 mm safety plugs.
more
Lamp socket on transparent acrylic base with screw connection for ordinary commercial filament bulbs for E14 sockets. Sockets for 4 mm safety plugs.
more
Set of "Conductors and Non-Conductors"
To investigate the various levels of conductivity of 8 different sample materials.
Scope of delivery: iron rod, aluminum rod, copper rod, steel rod, wooden rod, glass rod, plastic rod, cotton string ...
more
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
Material: Copper
Length: 100 m
Diameter: 0.3 mm
more
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
Material: Iron (without coating)
Length: 100 m
Diameter: 0.3 mm
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Resistance Wires
Metal wires on bobbins, e.g. for experiments to investigate how resistance depends on the material, cross-sectional area and length of the wire.
more
Holder on an acrylic base with two crocodile clips for connecting loose resistors and other electronic components or samples from the “Conductors and Insulators” set. Sockets for 4-mm safety plugs.
more
Double-pole double throw (DPDT) change-over switch in a robust casing with high dielectric strength. Connection is made via 4-mm safety sockets.
Dimensions: 112 x 62 x 45 mm approx.
Weight: 95 g approx.
more
Assembly Kit “Bell, Relay and Bimetallic Switch ” Equipment kit comprising materials to assemble electromagnetic switches and bimetallic switches. Base plate in mm (L x W x H): 200 x 140 x 40 Total weight of set: approx. 1.6 kg Scope of supply ...
more
Connection rod on insulated base with three 4 mm cross holes and one axial 4 mm bore hole used to secure components with 4 mm connectors or to plug in 4 mm cables. At the top end spring-loaded terminal socket used as a wire clamp.
Height: ...
more
Resistance Bridge used to measure resistances in bridge circuits and investigate voltage drops across wires. The device is only suitable for low voltages.
It consists of a rail with a scale mounted at two points and a resistance wire stretched ...
more
The set of two resistor wires of resistance 22 Ω and length 1.5 m can be used as connecting wires in experiments involving model overhead power lines or transmission lines for the transmission of electrical energy. In such experiments they ...
more
Clamp for the insulated securing of electrical components with 4 mm connectors. A PVC isolator is used to isolate sections from each other. Upper section features two 4 mm cross bore holes and one 6 mm hole with clamping screw. Lower section ...
more
Resistance decades which can be mechanically connected to one another, e.g. in order to assemble a Wheatstone bridge. With color-coded safety sockets and control knob for setting measurement resistances in 10 steps. Includes 25-cm safety patch ...
more
Resistance decades which can be mechanically connected to one another, e.g. in order to assemble a Wheatstone bridge. With color-coded safety sockets and control knob for setting measurement resistances in 10 steps. Includes 25-cm safety patch ...
more
Resistance decades which can be mechanically connected to one another, e.g. in order to assemble a Wheatstone bridge. With color-coded safety sockets and control knob for setting measurement resistances in 10 steps. Includes 25-cm safety patch ...
more
Resistance decades which can be mechanically connected to one another, e.g. in order to assemble a Wheatstone bridge. With color-coded safety sockets and control knob for setting measurement resistances in 10 steps. Includes 25-cm safety patch ...
more
Resistance decades which can be mechanically connected to one another, e.g. in order to assemble a Wheatstone bridge. With color-coded safety sockets and control knob for setting measurement resistances in 10 steps. Includes 25-cm safety patch ...
more
Four resistance decades in a single housing, can be used individually or in combination, e.g. for setting up a Wheatstone bridge. Can be set using control knob, with decade scale.
Output: via 4 mm safety sockets
Max. current: 700 mA (1 Ω ...
more
Capacitance decades which can be mechanically connected to one another. With color-coded safety sockets and control knob for setting capacitances in 10 steps. Includes 25 cm safety patch cord.
Nominal voltage: 350 V DC
Connections: 4 mm safety ...
more
Variable inductance decade in impact-resistant plastic housing. This series incorporates mechanically stable components, a slide switch for setting measurement ranges and 4-mm safety sockets to ensure that all connections are safe.
...
more
Capacitance decade in impact-resistant plastic housing. This series incorporates mechanically stable components, a slide switch for setting measurement ranges and 4-mm safety sockets to ensure that all connections are safe.
Measuring range ...
more
Set of 15 patch cords, 75 cm long, 5 of each color in red, black and blue. Copper wire encased in highly flexible PVC for use with low-voltage electrical circuits. Wires are equipped at either end with a laminated plug and a fully-insulated ...
more
For electrical circuits with low voltages and high currents; copper wire encased in highly flexible PVC; equipped at either end with a laminated plug and a fully-insulated axial jack for connecting additional patch cords.
Wire cross ...
more
For electrical circuits with low voltages and high currents; copper wire encased in highly flexible PVC; equipped at either end with a laminated safety plug and a fully-insulated axial jack for connecting additional patch cords.
Wire ...
more
Set of 10 screw-in sockets for lamps with E10 screw thread. Electrical contact is made via uninsulated wires passing through the connecting eyelets in the base or via crocodile clips.
Base: 28 mm diam.
more
E10 lamp socket attached to a safe box for building simple electric circuits using safety experiment leads. Printed with a circuit symbol.
Maximum voltage: 12 V
Maximum current: 2 A
Dimensions: 135x85x40 mm³
more
The waterproof 4.7 kΩ NTC thermistor probe is used in experiments to study how the resistance of a negative temperature coefficient semiconducting thermistor depends on temperature. The probe is immersed in a water bath and the current ...
more
The waterproof 100 Ω PTC thermistor probe is used in experiments to study how the resistance of a positive temperature coefficient semiconducting thermistor depends on temperature. The probe is immersed in a water bath and the current ...
more