Measurement Amplifier U (115 V, 50/60 Hz)

Measurement Amplifier U (115 V, 50/60 Hz), 1020744 [U8557560-115], Measuring Amplifier
Measurement Amplifier U (115 V, 50/60 Hz), 1020744 [U8557560-115], Measuring Amplifier
$ 707.00
More on the way
Measurement amplifier U amplifies low-amplitude measurement signals from low-resistance signal sources for measurement with any chosen voltmeter or oscilloscope. By using an external shunt resistor it is also possible to measure small currents. Offset voltages can be compensated using coarse and fine offset adjustment knobs. Amplification (gain) can be selected in ranges from 0 to 5 powers of ten. High-frequency noise or other interference signals are filtered out by means of a low-pass filter with step-wise selectable time constants between 0 and 3 seconds. The output voltage has the same sign as the input voltage.

Input resistance:                             10 kohm
Output resistance:                          300 ohm
Offset voltage drift:                          < 2 μV/K (after 15 mins.
operation approx.)
Gain factors:                                    100; 101; 102; 103; 104; 105
Tolerance for gain factors:            < 2.5 %
Input voltage:                                   max. ±12 V  
(overload protected for
brief transients up to 100 V)
Output voltage:                                0 … ±12 V
(short-circuit protected)
Power supply (via
plug-in supply provided):               12 V AC
Ambient temperature:                     5°C ... 23°C … 40°C
Storage temperature:                      -20 … 70°C
Relative humidity:                           <85%
no condensation
Operational alignment:                  Horizontal
Contamination level:                      2
Protection class:                              IP20
Dimensions:                                    170x105x50 mm3 approx.
Weight:                                             335 g approx.


Measurement and frequency ranges (relative to 1 V output voltage)

Gain Input voltage Current through
RShunt = 100 ohm
Frequency
100 1 V 10 mA 0 … 25 kHz
101 100 mV 1 mA 0 … 25 kHz
102 10 mV 100 µA 0 … 25 kHz
103 1 mV 10 µA 0 … 20 kHz
104 100 µV 1 µA 0 … 7 kHz
105 10 µV 100 nA 0 … 7 kHz
 

Cut-off frequency for switchable low-pass filter

Time constant Cut-off frequency
0.0 s See Table 1
0.1 s 1.6 Hz
0.3 s 0.5 Hz
1.0 s 0.16 Hz
3.0 s 0.05 Hz

Item No.: 1020744 [U8557560-115]
Weight 1.63 lb
Brand 3B Scientific
  • Secure online payment with SSL
  • Expert advice
  • Financing available
  • Easy returns & exchanges
  • International shipping available
Service hotline:
1-888-326-6335
Add to cart

Customers who bought this item also bought these items:
Thermopile, 1000824 [U8441301], Greenhouse Effect
$ 374.00
by 3B Scientific
Barrel Foot, 500 g, 1001046 [U8611210], Stands, Clamps and Accessories
$ 55.00
by 3B Scientific
Stefan Boltzmann lamp, 1008523 [U8490050], Optical Lamps on Stem
$ 174.00
by 3B Scientific
Digital Multimeter P3340, 1002785 [U118091], Hand-held Digital Measuring Instruments
$ 76.00
by PeakTech
Intermediate Nuclear Lab Station, PC or Mac, U41400, Lab Stations
$ 2,165.00
by Spectrum Techniques
Set of 8 sources, U41513, Radioactivity
$ 440.00
by Spectrum Techniques
Leslie's Cube, 1000835 [U8442835], Heat Flow and Radiation of Heat
$ 312.00
by 3B Scientific
Coil D with 600 Turns, 1000988 [U8497430], Demountable Transformer D
$ 165.00
by 3B Scientific
Rotating Base for Leslie Cube, 1017875 [U8557350], Heat Flow and Radiation of Heat
$ 54.00
by 3B Scientific